Requirement: No. of Shafts - Two/Ratio 1:1
Power Rating - 0.33 KW/Input Speed 1440 RM
Daily Service - 12 Hrs/day
Load = Uniform/Prime Mover - Electric Motor
To Calcucate:
Torque (Kpm) = KW X 974 X SF = 0.33 X 974 X 1 = 0.23 Kpm
RPM 1400
Power (KW) = Kpm X RPM = 0.23 X 1400 = 0.33 KW
974 974
|